Air outlet size of central air conditioner

Author:Source:Visits:Date:2013/8/28

The central air conditioning outlet "has always been about" beauty ", both side air or air, can be naturally hidden in the partial ceiling, far from looking like a piece of art, the decoration is in line with modern taste. Because the general indoor can only see the outlet of central air conditioner, so the central air-conditioning outlet size is critical, if the design is not reasonable so the follow-up will cause visual pollution, and to bring a lot of trouble.
central air-conditioning outlet size is the number of
and the traditional cabinet, wall hanging, with interior decoration simultaneously, and indoor hidden machine installed in the ceiling, so the central air conditioning / air outlet size is not specified. In the actual design and installation process, it needs to be based on home decoration, flexible flexibility, the size of the outlet / back depends on the size of the indoor machine.
general, central air-conditioning outlet size is, the wind is 15cm*60-100cm, return to 26cm*60-100cm, the access port is 35cm*35cm, the width of the air outlet and the return air can be, but the length according to the indoor environment to design reasonable length and decoration.
central air-conditioning outlet design standard
central air-conditioning outlet size depends on the size of the indoor machine, if the central air-conditioning outlet size is too large, the wind pipe is too long, then the airflow velocity will decrease, thus affecting the use of air conditioning effect; if the central air-conditioning outlet size is too small, then the flow velocity becomes large, which leads to the wind blowing straight body caused discomfort, may also lead to excessive noise.
central air-conditioning air supply method mainly has the side to send the next, send the next, side to side back to the three, because the wind is generally greater than the central air conditioning return air outlet, so the air when the air inlet area than the outlet of the large. In addition, the central air conditioning outlet is best not to set up the lamp slot, it is easy to block the flow of hot air to reach the area of activity, the effect of heating.